Sign In | Join Free | My tjskl.org.cn
China Macylab Instruments Inc. logo
Macylab Instruments Inc.
Macylab Instruments Inc. Technology - because you change
Active Member

11 Years

Home > Dual Beam Spectrophotometer >

Icp Inductively Coupled Plasma Optical Emission Spectroscopy Czerny-Turner

Macylab Instruments Inc.
Contact Now

Icp Inductively Coupled Plasma Optical Emission Spectroscopy Czerny-Turner

  • 1
  • 2
  • 3

Brand Name : Macylab

Model Number : ICP-6800

Certification : CE ISO ROHS FCC FAD

Place of Origin : China

MOQ : 1pcs

Price : USD33900/Set

Payment Terms : Western Union, MoneyGram, T/T, L/C

Supply Ability : 5000Set / year

Delivery Time : 20-300days

Packaging Details : Wood Box

Name : Inductively Coupled Plasma Optical Emission Spectrometer

key words : Indu Coupled Plasma Optical Emission Spectroscopy ICP Czerny-Turnerctively

Optics : Czerny-Turner

Output power : 800 -1200W

Frequency : 27.12MHz±0.05%

Frequency Stability : < 0.1%

Stability : RSD <1.5%

Output power Stability : < 0.3%

WxDxH : 125x69.3x64.5cm

Contact Now

Inductively Coupled Plasma Optical Emission Spectrometer ICP-6800

Inductively coupled plasma emission spectrometer(ICP6800) developed by Macylab Instruments with many years of technology accumulation. It is used to measure traces and traces of various substances (dissolvable in hydrochloric acid, nitric acid, hydrofluoric acid, etc.),and the content of metal elements or non-metallic elements. It is stable and reliable and with high degree of automation and easy operation.

At present, instruments are widely applied in various fields such as rare earth, geology, metallurgy, chemical industry, environmental protection, clinical medicine, petroleum products, semiconductor, food, biological samples, criminal science, agricultural research and so on.

Main features


Performance stability

The use of all-solid-state rf power supply, with small size, high efficiency, stable output power, with a variety of protection functions and many other advantages, the load using fully automatic matching technology, matching speed, improve the efficiency of the use of power supply and the stability of the instrument, and make the whole ignition process simple and convenient.

Injection automation

Adopting four-channel automatic design, the rotational speed can be set up according to the test demand to adjust the flow rate, carrier gas, plasma gas, auxiliary gas are all controlled by advanced mass flow controller, at the same time can be equipped with imported high salt nebulizer, imported hydrofluoric nebulizer and so on to meet the customer's various test needs.

Precision analysis

The middle step grating prism cross dispersion mode is adopted, there is no moving optical element, the ultra low stray light design is combined with the unique optical design, nitrogen distributed blowing, imported optical elements, intelligent and accurate automatic wavelength calibration algorithm.

Quick test

In American thermoelectric CID detector, the 160-1000nm range is continuously covered, and the intensity integral values of all analytical spectral lines are read out at one exposure to speed up the analysis.


Technical parameters

RFPower technical parameter

Circuit type

solid-state RF Power supply, with function of automatch

Frequercy

27.12MHz±0.05%

Frequency Stablity

<0.1%

Power Output

800W-1500W

Power Output Stability

<0.3%

Escaped RF radiation

30cm away from the instrument, electric fiekd: E<2Vtm

Sampling System Technical Parameter

Output working coil imer diameter

25mm

Torpue tube

Three concentric, extemal diameter 20mm

Coaxial nebulizer

Outer dameter 6mm

Double barrel atomizing chamber

Outer diameter 34mm

Gas Flow Controls

Plasma Argon Flowmeter

(100-1000)L/h(1.6-16L/min)

Auxiliary Argon Fiowmeter

(100-1000)L/h(0.16-1.6L/min)

Auxiliary Carrier Argon Flowmeter

(100-1000)L/h(0.16-1.6L/min)

Pressune Maintaining Value

(0-0.4MPa)

Cooling Water:Temperature

20-25ºC,Rate of Flow>5L/min,Hydraulic Pressure>0.1MPa

Spectrometer

Optics

Czerny-Turner type

Focal length

1000 mm

Grating

Ion Beam Etching Holographic Grating, 3600L/mm or 2400L/mm

Reciprocal linear dispersion

0.26nm/mm

Resolution

≤0.007nm(3600 line grating); ≤0.015nm(2400 line grating)

Wavelength range

3600 line grating:(190nm~500) nm; 2400 line grating:(190nm~800) nm

Minimum pace of stepping motor

≤0.0006 nm

Exit Slit

12μm

Entrance Slit

10μm

Photoelectric Converter Performance

Photomultiplier tube specification

R293/R928

Negative HV on PMT

0-1000V

Stability

<0.05%

Overall Performance

Wavelength range of scanning: 195nm~500nm(3600L/mm line grating);195nm~800nm(2400L/mm line grating)

Repeatability: RSD(Relative Standard Deviation)≤1.5%

Stability: RSD(Relative Standard Deviation) ≤2%

Detection Limits (µg/L):

Element WL(nm) Limit   Element WL(nm) Limit
La 408.672 <3.0   Cr 267.716 <5.0
Ce 413.765 <5.0   Al 396.152 <5.0
Pr 414.311 <5.0   Zr 343.823 <5.0
Nd 401.225 <5.0   Ag 328.068 <3.0
Sm 360.946 <10.0   Sr 407.771 <1.0
Eu 381.967 <1.0   Au 242.795 <5.0
Gd 342.247 <10.0   Pt 265.945 <5.0
Tb 350.917 <3.0   Pd 340.458 <5.0
Dy 353.170 <3.0   Ir 224.268 <10.0
Ho 345.600 <3.0   Rh 343.489 <10.0
Er 337.271 <3.0   Ru 240.272 <5.0
Tm 313.126 <3.0   Ba 455.403 <1.0
Yb 369.419 <1.0   As 228.812 ≤15
Lu 261.541 <3.0   Sb 206.833 ≤15
Y 371.030 <1.0   Bi 223.061 ≤10
Sc 335.373 <1.0   Hg 253.652 ≤15
Ta 226.230 <5.0   Pb 220.353 ≤15
Nb 313.340 <5.0   Ga 294.364 ≤10
Mn 257.610 <3.0   Se 203.985 ≤10
Mg 279.553 <1.0   Sn 242.949 ≤20
B 249.773 <10.0   Te 214.281 ≤10
Zn 213.856 <3.0   Ta 226.230 ≤5.0
Co 228.616 <3.0   Th 283.730 ≤10
Si 251.611 <10.0   Tl 276.787 ≤30
Ni 232.003 <5.0   Re 227.525 ≤5
Cd 226.502 <3.0   Ge 209.426 ≤15
Fe 239.562 <3.0   Os 225.585 ≤1
Ca 393.366 <1.0   W 207.911 ≤10
Mo 281.615 <5.0   Cu 324.754 <3.0
V 310.230 <5.0   Li 670.784 ≤3
Be 313.041 <1.0   Na 588.995 ≤20
Ti 334.941 <3.0   K 766.490 ≤60

Icp Inductively Coupled Plasma Optical Emission Spectroscopy Czerny-Turner


Application Field Icp Inductively Coupled Plasma Optical Emission Spectroscopy Czerny-Turner

Certificate Icp Inductively Coupled Plasma Optical Emission Spectroscopy Czerny-Turner

Icp Inductively Coupled Plasma Optical Emission Spectroscopy Czerny-Turner

Company profile

Macy(China) Instruments Inc is part of Shanghai Macylab Instrument Inc, is a high-tech enterprise with independent intellectual property rights . Macy hold the pioneering concept "technology - because you change " , and as a business purpose, and constantly explore, bold innovation. Especially in the field of analytical instruments ,Macy constantly develop advanced products that enable Macy to become a high-quality instrument resource supplier and leader.

Icp Inductively Coupled Plasma Optical Emission Spectroscopy Czerny-Turner

Exhibitions

Icp Inductively Coupled Plasma Optical Emission Spectroscopy Czerny-Turner

Icp Inductively Coupled Plasma Optical Emission Spectroscopy Czerny-Turner


Product Tags:

inductively coupled plasma optical emission spectroscopy

      

icp inductively coupled plasma optical emission spectroscopy

      

icp inductively coupled plasma optical emission spectrometer

      
Quality Icp Inductively Coupled Plasma Optical Emission Spectroscopy Czerny-Turner for sale

Icp Inductively Coupled Plasma Optical Emission Spectroscopy Czerny-Turner Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Macylab Instruments Inc.
*Subject:
*Message:
Characters Remaining: (0/3000)